Honeywell aquastat manuals
0 L High Limit Aquastat Controller has adjustable set point. Cl L models available for use with immersion wells or for direct immersion if faster response is needed. 0 A factory-set stop is available on L to prevent setting the control at too high a temperature. LA,E,J AQUASTAT® RELAYS 3 —9 Table 2. Standard L Model Specifications. a See Fig. 1 for case dimensions. b Number of V Zone Valves that can be powered from the L without additional transformer(s). A load is the maximum permissible File Size: KB. Honeywell Aquastat LE Manuals Manuals and User Guides for Honeywell Aquastat LE. We have 2 Honeywell Aquastat LE manuals available for free PDF download: Product Data, Installation Instructions Manual. Honeywell Aquastat LE Product Data (12 pages) immersion type hydronic controllers.
Aquastat Relay separately; refer to form , Wells MANUAL SWITCH 1K1 C1 B3 B2 B1 C2 L2 LJ MB. LA,E,J AQUASTATfi RELAYS 5 Š12 Fig. 5. Wiring LA in oil-fired, forced hot water, tankless, zoned, pump system. Fig. 6. Wiring LE with internal plug directly to vent damper in hydronic intermittent pilot system. LA,E,J AQUASTAT® RELAYS 3 —9 Table 2. Standard L Model Specifications. a See Fig. 1 for case dimensions. b Number of V Zone Valves that can be powered from the L without additional transformer(s). A load is the maximum permissible when ambient temperature exceeds 77°F (25°C). Honeywell Aquastat LE Manuals User Guides. User Manuals, Guides and Specifications for your Honeywell Aquastat LE Relays. Database contains 2 Honeywell Aquastat LE Manuals (available for free online viewing or downloading in PDF): Installation instructions manual, Product data.
Honeywell LA,B,E,H Aquastat® Controllers Installation Manual Honeywell LA APPLICATION. These boiler-mounted, immersion type controllers operate in response to temperature changes in hydronic heating systems. LA breaks the circuit on a temperature rise to the control setting. It is used for high limit or low limit control. The LA,C and LA,C,L Oil Electronic Aquastat Controllers are primary safety limit-rated devices designed for use with oil fired boilers with line voltage burners and circulators. Many boilers do not include wiring or control compartments as part of the design, but are provided with an integral, replaceable, immersion well that is the. LA Aquastat Controller fits the old immersion well spud, this immersion well does not need to be replaced. 2. If the immersion well is to be replaced and if the system is filled, drain the system to a point below the boiler tapping. 3. Remove plug (or old immersion well) from boiler tapping. 4. Install new immersion well (not included). When a.
0コメント